Installation

Read the installation instructions in the installation sheet and the information on this page before you connect the StarLeaf GTm 5140 to its power source.

Install the StarLeaf GTm 5140 only in accordance with the installation instructions in the GTm 5140 Installation and Admin Guide.

Ventilation

Do not block any of the ventilation openings of the GTm 5140.

Allow an adequate space around the unit to promote a good air flow for cooling of the GTm 5140. Do not block the fan inlet or outlets. Ensure that the fan intake is not placed inline with the outlet from any other fan or convection cooled device. To avoid blocking the lower side vents do not operate the GTm 5140 on a carpet or soft surface.

Servicing

Do not remove the cover of the GTm 5140. There are no user-serviceable parts. If you open the GTm 5140 or remove its cover you will invalidate the warranty.

Power requirements

The GTm 5140 must be connected to the AC/DC adaptor approved by StarLeaf (StarLeaf part number 712-00090 / Manufacturing part number FSP065-10AABA).

The table below shows the power ratings of the GTm 5140:

Table 1: AC power ratings

Rating Value
Supply voltage range 100 to 240V 50-60Hz
Current rating 1.5A maximum

Operating environment

The GTm 5140 must only be used indoors and within the following environmental conditions:

Table 2: Operating environment

Environment Temperature Humidity
Operating environment 0°C to 50°C 10% to 95% (non-condensing)
Non-operating environment -40°C to 60°C 10% to 95% (non-condensing)

Approvals information

EU/EEC

The Declaration of Conformity is available on request.

Directive 2006/95/EC and 2014/35/EU (Low Voltage Directive):

  • Standard EN 60950-1

Directive 2004/108/EC and 2014/30/EU (EMC Directive):

  • Standard EN 55022 Class A
  • Standard EN 55032
  • Standard EN 55024
  • Standard EN 61000-3-2
  • Standard EN 61000-3-3